From 19d7334d2912e8be3c1a4e5080f34c5b95876e3c Mon Sep 17 00:00:00 2001 From: Blaise Thompson Date: Fri, 7 May 2021 11:43:32 -0500 Subject: restructure galvanosynth --- galvanosyth/manual/manual.aux | 26 -------------------------- 1 file changed, 26 deletions(-) delete mode 100644 galvanosyth/manual/manual.aux (limited to 'galvanosyth/manual/manual.aux') diff --git a/galvanosyth/manual/manual.aux b/galvanosyth/manual/manual.aux deleted file mode 100644 index d69128f..0000000 --- a/galvanosyth/manual/manual.aux +++ /dev/null @@ -1,26 +0,0 @@ -\relax -\providecommand\hyper@newdestlabel[2]{} -\providecommand\HyperFirstAtBeginDocument{\AtBeginDocument} -\HyperFirstAtBeginDocument{\ifx\hyper@anchor\@undefined -\global\let\oldcontentsline\contentsline -\gdef\contentsline#1#2#3#4{\oldcontentsline{#1}{#2}{#3}} -\global\let\oldnewlabel\newlabel -\gdef\newlabel#1#2{\newlabelxx{#1}#2} -\gdef\newlabelxx#1#2#3#4#5#6{\oldnewlabel{#1}{{#2}{#3}}} -\AtEndDocument{\ifx\hyper@anchor\@undefined -\let\contentsline\oldcontentsline -\let\newlabel\oldnewlabel -\fi} -\fi} -\global\let\hyper@last\relax -\gdef\HyperFirstAtBeginDocument#1{#1} -\providecommand\HyField@AuxAddToFields[1]{} -\providecommand\HyField@AuxAddToCoFields[2]{} -\@writefile{toc}{\contentsline {section}{\numberline {1}Overview \& Performance}{1}{section.1}} -\@writefile{lof}{\contentsline {figure}{\numberline {1}{\ignorespaces Measured current versus set current. On this log-log plot, the entire set-point range of 10 $\mu $A to 9.99 mA can clearly be seen. For both outputs, agreement within measurement error is achieved from 0.30 mA to 9.99 mA. Unfortunately, both outputs become nonlinear at the lowest setpoints, systematically overshooting the desired current. For an unknown reason, the agreement is worse for the left-hand output. All readings were taken with a load of 100 $\Omega $. }}{2}{figure.1}} -\newlabel{fig:setpoint}{{1}{2}{Measured current versus set current. On this log-log plot, the entire set-point range of 10 $\mu $A to 9.99 mA can clearly be seen. For both outputs, agreement within measurement error is achieved from 0.30 mA to 9.99 mA. Unfortunately, both outputs become nonlinear at the lowest setpoints, systematically overshooting the desired current. For an unknown reason, the agreement is worse for the left-hand output. All readings were taken with a load of 100 $\Omega $}{figure.1}{}} -\@writefile{lof}{\contentsline {figure}{\numberline {2}{\ignorespaces Measured applied voltage versus load resistance. All readings were taken at a current set-point of 1 mA. The ``ideal'' ohms law behavior is represented by the grey diagonal line. Both outputs saturate at just above 13 V. }}{3}{figure.2}} -\newlabel{fig:load}{{2}{3}{Measured applied voltage versus load resistance. All readings were taken at a current set-point of 1 mA. The ``ideal'' ohms law behavior is represented by the grey diagonal line. Both outputs saturate at just above 13 V}{figure.2}{}} -\@writefile{toc}{\contentsline {section}{\numberline {2}Troubleshooting}{4}{section.2}} -\@writefile{toc}{\contentsline {section}{\numberline {3}Appendix}{5}{section.3}} -\@writefile{toc}{\contentsline {subsection}{\numberline {3.1}Parts}{6}{subsection.3.1}} -- cgit v1.2.3